TSK-001027 · Project design basis

Related Vinegar Recovery and pH-Treatment Changes to Wastewater BOD Loading, Discharge Limits and Historical Surcharges

Explore the capability, case, and equipment connections for this activity.

Conceptual engineering illustration: water environmental recovery
Conceptual engineering visualization · AI generated

Case Context

Centrifuge Installation and Interface Engineering ↗

Project Context

PRJ-A-012 · Centrifuge Installation and Interface Engineering ↗

Capabilities

Measures & Operating Context

MeasureValueType & meaningAttribution & operating context
BOD Allowance500 lb/dayOperating Control
Discharge criterion

Applies to: Related vinegar recovery and pH-treatment changes to wastewater BOD loading, discharge limits and historical surcharges

City receiver — BOD allowance — City receiver

BOD Exceedance Months7 monthsObservation
Historical observation

Applies to: Related vinegar recovery and pH-treatment changes to wastewater BOD loading, discharge limits and historical surcharges

12-month review — BOD exceedance months — 12-month review

Waste-Volume Exceedance Months11 monthsObservation
Historical observation

Applies to: Related vinegar recovery and pH-treatment changes to wastewater BOD loading, discharge limits and historical surcharges

12-month review — Waste-volume exceedance months — 12-month review

Weekly Discarded Vinegar and Sludge2,000 gal/weekBaseline
Historical design basis

Applies to: Related vinegar recovery and pH-treatment changes to wastewater BOD loading, discharge limits and historical surcharges

Membrane supplier cleaning — Weekly discarded vinegar and sludge — Membrane supplier cleaning

pH-Treatment Cost Reduction54,000 USD/yearEstimate
Projected benefit

Applies to: Related vinegar recovery and pH-treatment changes to wastewater BOD loading, discharge limits and historical surcharges

AFE option — pH-treatment cost reduction — AFE option

Combined Savings108,407 USD/yearEstimate
Projected benefit

Applies to: Related vinegar recovery and pH-treatment changes to wastewater BOD loading, discharge limits and historical surcharges

AFE option — Combined savings — AFE option

All Portfolio Connections

All portfolio connections (8)

Project Ownership and Delivery Context

Owned the full project lifecycle: capital planning and prioritization, need definition, feasibility and scope development, engineering and AFE justification, procurement and vendor coordination, construction sequencing and field oversight, commissioning, turnover, and post-startup support. Connected operating requirements with technical scope, funding decisions, execution readiness, and the needs of operations and maintenance.

Aligned skid utilities, electrical supply and process connections, and coordinated supplier startup and operator training. The resulting recovery of approximately 104,000 gallons per year connected separation engineering with usable product yield and reduced loss to the wastewater stream.