TSK-001007 · Vendor laboratory method

Filtration Supplier Tested Dilute Sodium-Hydroxide Neutralization of Residual Acetic Acid at Laboratory Scale; the Study Found No Identified Crystal-Like Particulate and Recommended Production Validation

Explore the capability, case, and equipment connections for this activity.

Conceptual engineering illustration: ceramic filtration
Conceptual engineering visualization · AI generated

Roles & Contributions

Case Context

Ceramic Filter CIP Interface Engineering ↗

Project Context

PRJ-A-010 · Ceramic Crossflow Filter System + Ion Exchange Trial ↗

Capabilities

Measures & Operating Context

MeasureValueType & meaningAttribution & operating context
Acetic Acid Sample Volume100 mLDesign Parameter
Vendor laboratory test condition

Applies to: Filtration supplier tested dilute sodium-hydroxide neutralization of residual acetic acid at laboratory scale; the study found no identified crystal-like particulate and recommended production validation

Acid sample — Acetic acid sample volume — Acid sample

Acetic Acid Concentration20 %Design Parameter
Vendor laboratory test condition

Applies to: Filtration supplier tested dilute sodium-hydroxide neutralization of residual acetic acid at laboratory scale; the study found no identified crystal-like particulate and recommended production validation

Acid sample — Acetic acid concentration — Acid sample

Sodium Hydroxide Volume660 mLObservation
Vendor laboratory result

Applies to: Filtration supplier tested dilute sodium-hydroxide neutralization of residual acetic acid at laboratory scale; the study found no identified crystal-like particulate and recommended production validation

Neutralizing solution — Sodium hydroxide volume — Neutralizing solution

Sodium Hydroxide Concentration2 %Design Parameter
Vendor laboratory test condition

Applies to: Filtration supplier tested dilute sodium-hydroxide neutralization of residual acetic acid at laboratory scale; the study found no identified crystal-like particulate and recommended production validation

Neutralizing solution — Sodium hydroxide concentration — Neutralizing solution

Reagent Dosing Rate60 mL/minDesign Parameter
Vendor laboratory test condition

Applies to: Filtration supplier tested dilute sodium-hydroxide neutralization of residual acetic acid at laboratory scale; the study found no identified crystal-like particulate and recommended production validation

Neutralization — Reagent dosing rate — Neutralization

Temperature Increase3 °FObservation
Vendor laboratory result

Applies to: Filtration supplier tested dilute sodium-hydroxide neutralization of residual acetic acid at laboratory scale; the study found no identified crystal-like particulate and recommended production validation

Neutralization — Approximately 3°F temperature increase, reported with ±1°F in the filtration supplier report, within one minute of dosing; membrane tolerance remained to be validated.

Total Suspended Solids106 mg/LObservation
Vendor laboratory result

Applies to: Filtration supplier tested dilute sodium-hydroxide neutralization of residual acetic acid at laboratory scale; the study found no identified crystal-like particulate and recommended production validation

Before neutralization — Total suspended solids — Before neutralization

Total Suspended Solids108 mg/LObservation
Vendor laboratory result

Applies to: Filtration supplier tested dilute sodium-hydroxide neutralization of residual acetic acid at laboratory scale; the study found no identified crystal-like particulate and recommended production validation

After neutralization — Total suspended solids — After neutralization

pH7 to 8 pH unitsObservation
Vendor laboratory result

Applies to: Filtration supplier tested dilute sodium-hydroxide neutralization of residual acetic acid at laboratory scale; the study found no identified crystal-like particulate and recommended production validation

After neutralization — pH — After neutralization

Initial Laboratory Temperature77 °FDesign Parameter
Vendor laboratory test condition

Applies to: Filtration supplier tested dilute sodium-hydroxide neutralization of residual acetic acid at laboratory scale; the study found no identified crystal-like particulate and recommended production validation

Before dosing — Reported 77°F ±1°F ambient/starting temperature

Laboratory Temperature After Dosing80 °FObservation
Vendor laboratory result

Applies to: Filtration supplier tested dilute sodium-hydroxide neutralization of residual acetic acid at laboratory scale; the study found no identified crystal-like particulate and recommended production validation

After first minute of dosing — Reported 80°F ±1°F; remained near this value for most dosing duration

Time to Reported Temperature Increase1 minObservation
Vendor laboratory result

Applies to: Filtration supplier tested dilute sodium-hydroxide neutralization of residual acetic acid at laboratory scale; the study found no identified crystal-like particulate and recommended production validation

Neutralization — Time to reported temperature increase

pH3 to 4 pH unitsObservation
Vendor laboratory result

Applies to: Filtration supplier tested dilute sodium-hydroxide neutralization of residual acetic acid at laboratory scale; the study found no identified crystal-like particulate and recommended production validation

Before neutralization — pH

SEM Image Magnification3,900 xDesign Parameter
Vendor laboratory method setting

Applies to: Filtration supplier tested dilute sodium-hydroxide neutralization of residual acetic acid at laboratory scale; the study found no identified crystal-like particulate and recommended production validation

membrane filter N66 NA disc examination — SEM image magnification

All Portfolio Connections

All portfolio connections (6)

Project Ownership and Delivery Context

Owned the full project lifecycle: capital planning and prioritization, need definition, feasibility and scope development, engineering and AFE justification, procurement and vendor coordination, construction sequencing and field oversight, commissioning, turnover, and post-startup support. Connected operating requirements with technical scope, funding decisions, execution readiness, and the needs of operations and maintenance.

Compared filtration options against demand and lifecycle requirements, integrated CIP and instrumentation with dedicated electrical feeds, and developed clean-water-flux tracking and maintenance follow-up. Ion-exchange testing extended the investigation into product clarity and quality, while modular expansion planning connected the equipment choice with future operating demand.

Related Analysis and Application Artifacts