CASE-019 · Engineering case

Ceramic Filter CIP Interface Engineering

Coordinated CIP automation to restore membrane performance while reducing manual cleaning and downtime.

Conceptual engineering visualization: Ceramic Filter CIP Interface Engineering
Conceptual engineering visualization · AI generated

Why the Work Mattered

Purpose and Operating Need

Coordinated CIP automation to restore membrane performance while reducing manual cleaning and downtime.

Engineering Approach

Engineering Approach

Coordination scope: automated CIP sequencing, NaOH /NaOCl cleaning, bypass/recirculation loops, HMI controls, membrane testing, and clean-water flux validation.

Outcome & Engineering Context

Coordinated CIP automation to restore membrane performance while reducing manual cleaning and downtime.

Workstream Results & Impact

Workstream Portfolio Rollup

18,317,000 USD

Wine Clarification and Vinegar Polishing Modernization

Recorded workstream portfolio reference. This is the workstream-level value and is not a project expenditure or a new total of reassigned projects.

Measures & Operating Detail

MeasureValueType & meaningAttribution & operating context
Time< 5 minutesObservation
Recorded operator interaction

Applies to: Ceramic Filter CIP Interface Engineering

Ceramic filtration automated operation — Recorded operator interaction of less than 5 minutes for the automated filtration/CIP arrangement.

Operating Measure> 50 %Actual Result
Recorded operating improvement

Applies to: Ceramic Filter CIP Interface Engineering

ceramic-filter operation — Recorded increase of more than 50% in run time between cleaning cycles; separate from the laboratory flux-recovery measurement.

Operating Measureapproximately 90 %Baseline
Vendor laboratory baseline

Applies to: Reviewed the vendor filterability study as a design baseline for ceramic filtration: membrane flux, pore size, clean-water-flux recovery after CIP and filtrate turbidity

study, 2018 — after one CIP — Clean-water-flux recovery in the filtration supplier vendor study.

Turbidity0.26 to 0.39 NTUBaseline
Vendor laboratory baseline

Applies to: Reviewed the vendor filterability study as a design baseline for ceramic filtration: membrane flux, pore size, clean-water-flux recovery after CIP and filtrate turbidity

study, 2018 — filtrate — Filtrate turbidity in the filtration supplier vendor study.

Proposed Concentrate Sample Volume500 mLDesign Parameter
Vendor test proposal

Applies to: Coordinated and reviewed filtration supplier's laboratory cleanability study, using the vendor's neutralization, temperature and particulate findings to inform a production-validation decision

Proposed input — Proposed concentrate sample volume

Proposed PES Membrane Pore Size0.2 µmDesign Parameter
Vendor test proposal

Applies to: Coordinated and reviewed filtration supplier's laboratory cleanability study, using the vendor's neutralization, temperature and particulate findings to inform a production-validation decision

Proposed laboratory filtration — Proposed PES membrane pore size

Proposed Neutralization Endpoint7 pH unitsTarget
Vendor test proposal

Applies to: Coordinated and reviewed filtration supplier's laboratory cleanability study, using the vendor's neutralization, temperature and particulate findings to inform a production-validation decision

Proposed endpoint — Proposed neutralization endpoint

Acetic Acid Sample Volume100 mLDesign Parameter
Vendor laboratory test condition

Applies to: Filtration supplier tested dilute sodium-hydroxide neutralization of residual acetic acid at laboratory scale; the study found no identified crystal-like particulate and recommended production validation

Acid sample — Acetic acid sample volume — Acid sample

Acetic Acid Concentration20 %Design Parameter
Vendor laboratory test condition

Applies to: Filtration supplier tested dilute sodium-hydroxide neutralization of residual acetic acid at laboratory scale; the study found no identified crystal-like particulate and recommended production validation

Acid sample — Acetic acid concentration — Acid sample

Sodium Hydroxide Volume660 mLObservation
Vendor laboratory result

Applies to: Filtration supplier tested dilute sodium-hydroxide neutralization of residual acetic acid at laboratory scale; the study found no identified crystal-like particulate and recommended production validation

Neutralizing solution — Sodium hydroxide volume — Neutralizing solution

Sodium Hydroxide Concentration2 %Design Parameter
Vendor laboratory test condition

Applies to: Filtration supplier tested dilute sodium-hydroxide neutralization of residual acetic acid at laboratory scale; the study found no identified crystal-like particulate and recommended production validation

Neutralizing solution — Sodium hydroxide concentration — Neutralizing solution

Reagent Dosing Rate60 mL/minDesign Parameter
Vendor laboratory test condition

Applies to: Filtration supplier tested dilute sodium-hydroxide neutralization of residual acetic acid at laboratory scale; the study found no identified crystal-like particulate and recommended production validation

Neutralization — Reagent dosing rate — Neutralization

Temperature Increase3 °FObservation
Vendor laboratory result

Applies to: Filtration supplier tested dilute sodium-hydroxide neutralization of residual acetic acid at laboratory scale; the study found no identified crystal-like particulate and recommended production validation

Neutralization — Approximately 3°F temperature increase, reported with ±1°F in the filtration supplier report, within one minute of dosing; membrane tolerance remained to be validated.

Total Suspended Solids106 mg/LObservation
Vendor laboratory result

Applies to: Filtration supplier tested dilute sodium-hydroxide neutralization of residual acetic acid at laboratory scale; the study found no identified crystal-like particulate and recommended production validation

Before neutralization — Total suspended solids — Before neutralization

Total Suspended Solids108 mg/LObservation
Vendor laboratory result

Applies to: Filtration supplier tested dilute sodium-hydroxide neutralization of residual acetic acid at laboratory scale; the study found no identified crystal-like particulate and recommended production validation

After neutralization — Total suspended solids — After neutralization

pH7 to 8 pH unitsObservation
Vendor laboratory result

Applies to: Filtration supplier tested dilute sodium-hydroxide neutralization of residual acetic acid at laboratory scale; the study found no identified crystal-like particulate and recommended production validation

After neutralization — pH — After neutralization

Initial Laboratory Temperature77 °FDesign Parameter
Vendor laboratory test condition

Applies to: Filtration supplier tested dilute sodium-hydroxide neutralization of residual acetic acid at laboratory scale; the study found no identified crystal-like particulate and recommended production validation

Before dosing — Reported 77°F ±1°F ambient/starting temperature

Laboratory Temperature After Dosing80 °FObservation
Vendor laboratory result

Applies to: Filtration supplier tested dilute sodium-hydroxide neutralization of residual acetic acid at laboratory scale; the study found no identified crystal-like particulate and recommended production validation

After first minute of dosing — Reported 80°F ±1°F; remained near this value for most dosing duration

Time to Reported Temperature Increase1 minObservation
Vendor laboratory result

Applies to: Filtration supplier tested dilute sodium-hydroxide neutralization of residual acetic acid at laboratory scale; the study found no identified crystal-like particulate and recommended production validation

Neutralization — Time to reported temperature increase

pH3 to 4 pH unitsObservation
Vendor laboratory result

Applies to: Filtration supplier tested dilute sodium-hydroxide neutralization of residual acetic acid at laboratory scale; the study found no identified crystal-like particulate and recommended production validation

Before neutralization — pH

SEM Image Magnification3,900 xDesign Parameter
Vendor laboratory method setting

Applies to: Filtration supplier tested dilute sodium-hydroxide neutralization of residual acetic acid at laboratory scale; the study found no identified crystal-like particulate and recommended production validation

membrane filter N66 NA disc examination — SEM image magnification

CIP Flush Volumeapproximately 6,000 galObservation
Field observation

Applies to: Captured a complete ceramic-CIP waste stream, organized repeated multi-point sampling, and coordinated the wastewater receiver, internal stakeholders, filtration supplier and laboratories

Ceramic-CIP flush — CIP flush volume — Ceramic-CIP flush

Wastewater Flow30,000 to 40,000 GPDObservation
Field observation

Applies to: Captured a complete ceramic-CIP waste stream, organized repeated multi-point sampling, and coordinated the wastewater receiver, internal stakeholders, filtration supplier and laboratories

Contemporaneous plant sampling — Wastewater flow — Contemporaneous plant sampling

pH2 to 3 pH unitsObservation
Field observation

Applies to: Captured a complete ceramic-CIP waste stream, organized repeated multi-point sampling, and coordinated the wastewater receiver, internal stakeholders, filtration supplier and laboratories

Contemporaneous plant sampling — pH — Contemporaneous plant sampling

Sodium Concentration189 ppmObservation
Field observation

Applies to: Captured a complete ceramic-CIP waste stream, organized repeated multi-point sampling, and coordinated the wastewater receiver, internal stakeholders, filtration supplier and laboratories

Contemporaneous plant sampling — Sodium concentration — Contemporaneous plant sampling

Wastewater Flow10,000 to 15,000 GPDOperating Control
Receiver criterion

Applies to: Developed temporary containment and dilution measures and evaluated permanent alternatives against receiving-facility hydraulic, pH and sodium criteria

Receiving facility — Wastewater flow — Receiving facility

pH> 3 pH unitsOperating Control
Receiver criterion

Applies to: Developed temporary containment and dilution measures and evaluated permanent alternatives against receiving-facility hydraulic, pH and sodium criteria

Receiving facility — pH — Receiving facility

Sodium Concentration< 160 ppmOperating Control
Receiver criterion

Applies to: Developed temporary containment and dilution measures and evaluated permanent alternatives against receiving-facility hydraulic, pH and sodium criteria

Receiving facility — Sodium concentration — Receiving facility

Engineering scope and design basis

Approximately 90% flux recovery in the separate 2018 laboratory baseline.

CIP interface records cite less than five minutes of operator interaction and more than 50% increased run time between cleaning cycles. Approximately 90% flux recovery belongs to the separate 2018 laboratory baseline.

Actions, Methods & Controls

ACTIVITIES IN CONTEXT

Conceptual engineering illustration: project controls

TSK-000037 · Method

Coordinated Automated CIP Sequencing, NaOH /NaOCl Cleaning, Bypass/Recirculation Loops, HMI Controls, Membrane Testing, and Clean-Water Flux Validation

Ceramic Filter CIP Interface Engineering

Additional Technical Detail

Roles & contributions
  • Project Ownership

    Full lifecycle project ownership

    Owned the full project lifecycle: capital planning and prioritization, need definition, feasibility and scope development, engineering and AFE justification, procurement and vendor coordination, construction sequencing and field oversight, commissioning, turnover, and post-startup support. Connected operating requirements with technical scope, funding decisions, execution readiness, and the needs of operations and maintenance.

  • Internal Stakeholders and Wastewater Receiver

    Project Team Contribution

    Team Contribution

    Internal stakeholders and the wastewater receiver participated in waste sampling, handling criteria and temporary-disposition coordination.

  • Filtration Supplier

    Supplier Participation

    Vendor Contribution

    Filtration supplier performed the laboratory neutralization/cleanability trial, SEM/EDXS and related analysis and recommended production-scale testing.

Workstream context
Additional technical detail
Explore 17 detail records
  • Measure

    Less than five minutes operator interaction and more than 50% increased run time between cleaning cycles. The approximately 90% clean-water-flux recovery is a separate 2018 filtration supplier vendor-study baseline.

  • Test plan

    The proposed cleanability study sought to reduce post-filtration flush water using neutralization. It called for 500 mL Food and beverage manufacturer concentrate, 2% NaOH dosing at 60 mL/min to pH 7, ongoing agitation with periodic pH/temperature readings, 0.2 µm PES filtration and SEM examination for salts. Its overview also proposed three-vinegar XLab 5/PSD/TSS/turbidity work. The performed report instead records 100 mL 20% acetic acid and N66 disc examination; planned and executed protocols remain separate.

  • Acceptance criteria

    Proposed acceptance required acid neutralization without impairing ceramic membrane ceramics, a written report and subsequent site piloting/cleaning-cycle adjustment. The recovered lab report recommends production-scale testing and does not independently close the membrane-performance criterion.

  • Laboratory method

    Filtration supplier performed the bench trial in a laminar-flow hood using a sympHony pH meter; filtered the neutralized mixture through an membrane filter N66 NA disc; measured TSS by LSM 44 rev 00; and used SEM procedure LC014 plus EDXS elemental analysis. SEM/EDXS showed oxygen and carbon with no identified crystal-like deposits; a 3900x membrane image is retained as qualitative method evidence.

  • Laboratory interpretation

    The report found only a small TSS difference, 106 to 108 mg/L, and no observed crystals after neutralization. It explicitly left tolerance of the approximately 3°F temperature rise by ceramic membranes unresolved and recommended production-scale trial.

  • Vendor system operating description

    The filtration supplier system operating description records: Slide 34: example caustic cleaning includes water fill, caustic dose, heated concentrate/permeate circulation, chemical flush, cooling, drain, refill, and clean-water-flux measurement.

  • Vendor system operating description

    The filtration supplier system operating description records: Slide 35: caustic dose uses AV83/89 and P80; time-delay end.

  • Vendor system operating description

    The filtration supplier system operating description records: Slide 36: chemical-line flush uses AV82/89 and P80; time-delay end.

  • Vendor system operating description

    The filtration supplier system operating description records: Slide 37: heated concentrate circulation uses AV03/01, CV08 30 percent, P01 50 percent and P02; low TT02 closes AV32/34 cooling and opens AV31/33 steam; high TT02 opens cooling and closes steam; ends after TT02 confirmation and time delay.

  • Vendor system operating description

    The filtration supplier system operating description records: Slide 38: heated permeate circulation adds AV59 and uses the same flow and TT02 steam/cooling logic.

  • Vendor system operating description

    The filtration supplier system operating description records: Slide 39: heated backflush uses P03 approximately 100 percent and the approximately 5-second backflush sequence.

  • Vendor system operating description

    The filtration supplier system operating description records: Slide 40: heated TK01 flush uses P03 approximately 50 percent, approximately 5-second delay, and AV70/77.

  • Vendor system operating description

    The filtration supplier system operating description records: Slide 41: exact visual duplicate of slide 40.

  • Vendor system operating description

    The filtration supplier system operating description records: Slide 42: chemical flushing uses AV03/01/59/65/71/76, CV08 30 percent, FCV01.1 100 percent, P01 50 percent and P02; ends when water use is at least 2x or 3x system volume.

  • Vendor system operating description

    The filtration supplier system operating description records: Slide 43: system cooling uses AV03/01/59/32/34, CV08 30 percent, P01 50 percent and P02; ends at TT02 setpoint.

  • Vendor system operating description

    The filtration supplier system operating description records: Slide 44: clean-water-flux measurement uses AV03/01/59, P01 100 percent, approximately 30-second delay; exact source math object: CWF = FIT11 / (Filtration Area / TMP) = lmh/bar.

  • Vendor system operating description

    The filtration supplier system operating description records: Slide 45: system ends full of water.

All portfolio connections
All portfolio connections (40)
Project ownership and delivery context

Owned the full project lifecycle: capital planning and prioritization, need definition, feasibility and scope development, engineering and AFE justification, procurement and vendor coordination, construction sequencing and field oversight, commissioning, turnover, and post-startup support. Connected operating requirements with technical scope, funding decisions, execution readiness, and the needs of operations and maintenance.

Compared filtration options against demand and lifecycle requirements, integrated CIP and instrumentation with dedicated electrical feeds, and developed clean-water-flux tracking and maintenance follow-up. Ion-exchange testing extended the investigation into product clarity and quality, while modular expansion planning connected the equipment choice with future operating demand.