Measures & Operating Context

MeasureValueType & meaningAttribution & operating context
pH4 pH unitsObservation
Vendor laboratory result

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Decanter supplier rice-wine sample, 20 August 2024 — pH — Decanter supplier rice-wine sample, 20 August 2024

Brix12 °BxObservation
Vendor laboratory result

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Decanter supplier rice-wine sample, 20 August 2024 — Brix — Decanter supplier rice-wine sample, 20 August 2024

Density1.007 g/mLObservation
Vendor laboratory result

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Decanter supplier rice-wine sample, 20 August 2024 — Density — Decanter supplier rice-wine sample, 20 August 2024

Total Solids8.47 %Observation
Vendor laboratory result

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Decanter supplier rice-wine sample, 20 August 2024 — Total solids — Decanter supplier rice-wine sample, 20 August 2024

Suspended Solids3.06 %Observation
Vendor laboratory result

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Decanter supplier rice-wine sample, 20 August 2024 — Suspended solids — Decanter supplier rice-wine sample, 20 August 2024

Dissolved Solids5.41 %Observation
Vendor laboratory result

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Decanter supplier rice-wine sample, 20 August 2024 — Dissolved solids — Decanter supplier rice-wine sample, 20 August 2024

Spin Index2.2 reported indexObservation
Vendor laboratory result

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Decanter supplier rice-wine sample, 20 August 2024 — Spin index — Decanter supplier rice-wine sample, 20 August 2024

Laboratory Test Temperature23 °CDesign Parameter
Vendor laboratory test condition

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Decanter supplier rice-wine feasibility — Laboratory test temperature

Total Solids85,217 mg/LObservation
Vendor laboratory result

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Decanter supplier rice-wine sample, 20 August 2024 — Total solids

Suspended Solids30,767 mg/LObservation
Vendor laboratory result

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Decanter supplier rice-wine sample, 20 August 2024 — Suspended solids

Dissolved Solids54,450 mg/LObservation
Vendor laboratory result

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Decanter supplier rice-wine sample, 20 August 2024 — Dissolved solids

Particle-Size Median263.35049 µmObservation
Vendor laboratory result

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Laboratory-instrument supplier LA-960 analysis of rice-wine feed — Printed median 263.35049 µm; the same D50 statistic is printed 263.3505 µm in the cumulative table, so it is retained as one observation.

Particle-Size Mean343.91736 µmObservation
Vendor laboratory result

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Laboratory-instrument supplier LA-960 analysis of rice-wine feed — Particle-size mean read from the embedded analyzer image; median/D50 retain their printed precision

Particle-Size Mode482.8425 µmObservation
Vendor laboratory result

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Laboratory-instrument supplier LA-960 analysis of rice-wine feed — Particle-size mode read from the embedded analyzer image; median/D50 retain their printed precision

Particle Diameter at 10% Cumulative6.6742 µmObservation
Vendor laboratory result

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Laboratory-instrument supplier LA-960 analysis of rice-wine feed — Particle diameter at 10% cumulative read from the embedded analyzer image; median/D50 retain their printed precision

Particle Diameter at 90% Cumulative803.8865 µmObservation
Vendor laboratory result

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Laboratory-instrument supplier LA-960 analysis of rice-wine feed — Particle diameter at 90% cumulative read from the embedded analyzer image; median/D50 retain their printed precision

Analyzer Transmittance R91.9 %Observation
Vendor laboratory result

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Laboratory-instrument supplier LA-960 analysis of rice-wine feed — Analyzer transmittance R

Analyzer Transmittance B92.3 %Observation
Vendor laboratory result

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Laboratory-instrument supplier LA-960 analysis of rice-wine feed — Analyzer transmittance B

Cumulative Particle Distribution73.166 %Observation
Vendor laboratory result

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Undersize at 500 µm — Printed cumulative undersize at 500 µm

Cumulative Particle Distribution29.487 %Observation
Vendor laboratory result

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Undersize at 100 µm — Printed cumulative undersize at 100 µm

Cumulative Particle Distribution20.91 %Observation
Vendor laboratory result

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Undersize at 50 µm — Printed cumulative undersize at 50 µm

Cumulative Particle Distribution17.838 %Observation
Vendor laboratory result

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Undersize at 20 µm — Printed cumulative undersize at 20 µm

Cumulative Particle Distribution15.266 %Observation
Vendor laboratory result

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Undersize at 10 µm — Printed cumulative undersize at 10 µm

Cumulative Particle Distribution5.111 %Observation
Vendor laboratory result

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Undersize at 5 µm — Printed cumulative undersize at 5 µm

Cumulative Particle Distribution0 %Observation
Vendor laboratory result

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Undersize at 1 µm — Printed cumulative undersize at 1 µm

Cumulative Particle Distribution0 %Observation
Vendor laboratory result

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Undersize at 0.5 µm — Printed cumulative undersize at 0.5 µm

Cumulative Particle Distribution0 %Observation
Vendor laboratory result

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Undersize at 0.2 µm — Printed cumulative undersize at 0.2 µm

Test Centrifugal Acceleration1,000 gDesign Parameter
Vendor laboratory test condition

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Photographed spin condition 1 — Test centrifugal acceleration

Test Residence Time1 minDesign Parameter
Vendor laboratory test condition

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Photographed spin condition 1 — Test residence time

Test Centrifugal Acceleration1,000 gDesign Parameter
Vendor laboratory test condition

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Photographed spin condition 2 — Test centrifugal acceleration

Test Residence Time5 minDesign Parameter
Vendor laboratory test condition

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Photographed spin condition 2 — Test residence time

Test Centrifugal Acceleration3,000 gDesign Parameter
Vendor laboratory test condition

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Photographed spin condition 3 — Test centrifugal acceleration

Test Residence Time1 minDesign Parameter
Vendor laboratory test condition

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Photographed spin condition 3 — Test residence time

Test Centrifugal Acceleration3,000 gDesign Parameter
Vendor laboratory test condition

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Photographed spin condition 4 — Test centrifugal acceleration

Test Residence Time2 minDesign Parameter
Vendor laboratory test condition

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Photographed spin condition 4 — Test residence time

Test Centrifugal Acceleration3,000 gDesign Parameter
Vendor laboratory test condition

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Photographed spin condition 5 — Test centrifugal acceleration

Test Residence Time5 minDesign Parameter
Vendor laboratory test condition

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Photographed spin condition 5 — Test residence time

Test Centrifugal Acceleration4,900 gDesign Parameter
Vendor laboratory test condition

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Photographed spin condition 6 — Test centrifugal acceleration

Test Residence Time5 minDesign Parameter
Vendor laboratory test condition

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Photographed spin condition 6 — Test residence time

Test Centrifugal Acceleration6,500 gDesign Parameter
Vendor laboratory test condition

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Photographed spin condition 7 — Test centrifugal acceleration

Test Residence Time5 minDesign Parameter
Vendor laboratory test condition

Applies to: Decanter supplier characterized the rice-wine sample, varied g-force and residence time, found decanter and sedicanter separation feasible, and recommended dynamic pilot testing at the required clarity and throughput

Photographed spin condition 7 — Test residence time