| Oil-Change Procedure Duration | 10 min | Observation Vendor training record | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation Centrifuge supplier startup, 2024-10-22 — Centrifuge supplier reported demonstrating the ten-minute oil-change process during operator training at the startup. |
| Flow | 30 GPM | Observation Vendor trial observation | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation Centrifuge supplier trial, 22–23 October 2024 — Initial Apple Wine startup — Vendor-reported initial apple wine startup: flow. |
| Outlet Backpressure | 150 psi | Observation Vendor trial observation | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation Centrifuge supplier trial, 22–23 October 2024 — Initial Apple Wine startup — Vendor-reported initial apple wine startup: outlet backpressure. |
| Flow | 30 GPM | Observation Vendor trial observation | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation Centrifuge supplier trial, 22–23 October 2024 — After inline-to-lab scaling — Vendor-reported after inline-to-lab scaling: flow. |
| Outlet Backpressure | 100 psi | Observation Vendor trial observation | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation Centrifuge supplier trial, 22–23 October 2024 — After inline-to-lab scaling — Vendor-reported after inline-to-lab scaling: outlet backpressure. |
| Outlet Turbidity | 17 NTU | Observation Vendor trial observation | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation Centrifuge supplier trial, 22–23 October 2024 — After inline-to-lab scaling — Vendor-reported after inline-to-lab scaling: outlet turbidity. |
| Flow | 40 GPM | Observation Vendor trial observation | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation Centrifuge supplier trial, 22–23 October 2024 — Raised flow — Vendor-reported raised flow: flow. |
| Outlet Backpressure | 100 psi | Observation Vendor trial observation | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation Centrifuge supplier trial, 22–23 October 2024 — Raised flow — Vendor-reported raised flow: outlet backpressure. |
| Outlet Turbidity | 20 NTU | Observation Vendor trial observation | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation Centrifuge supplier trial, 22–23 October 2024 — Raised flow — Vendor-reported raised flow: outlet turbidity. |
| Flow | 40 GPM | Observation Vendor trial observation | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation Centrifuge supplier trial, 22–23 October 2024 — Reduced outlet backpressure — Vendor-reported reduced outlet backpressure: flow. |
| Outlet Backpressure | 75 psi | Observation Vendor trial observation | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation Centrifuge supplier trial, 22–23 October 2024 — Reduced outlet backpressure — Vendor-reported reduced outlet backpressure: outlet backpressure. |
| Outlet Turbidity | 20 NTU | Observation Vendor trial observation | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation Centrifuge supplier trial, 22–23 October 2024 — Reduced outlet backpressure — Vendor-reported reduced outlet backpressure: outlet turbidity. |
| Flow | 50 GPM | Observation Vendor trial observation | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation Centrifuge supplier trial, 22–23 October 2024 — Following-day repeated run — Vendor-reported following-day repeated run: flow. |
| Outlet Backpressure | 100 psi | Observation Vendor trial observation | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation Centrifuge supplier trial, 22–23 October 2024 — Following-day repeated run — Vendor-reported following-day repeated run: outlet backpressure. |
| Outlet Turbidity | 23 NTU | Observation Vendor trial observation | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation Centrifuge supplier trial, 22–23 October 2024 — Following-day repeated run — Vendor-reported following-day repeated run: outlet turbidity. |
| Stable Production Duration | approximately 5 h | Observation Vendor trial observation | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation Centrifuge supplier trial, 22–23 October 2024 — Vendor reported approximately five hours without production issues at the stated settings after the air adjustment. |
| Additional Air-Pressure Adjustment | 5 psi | Observation Vendor trial observation | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation Centrifuge supplier trial, 22–23 October 2024 — Vendor increased supply air another 5 psi after a low-pressure alarm. |
| Solids Discharge Interval | 4 to 5 min | Observation Vendor trial observation | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation Centrifuge supplier trial, 22–23 October 2024 — Vendor-reported discharge interval at 50 GPM; solids packing and post-rinse needs varied with flow. |
| Solids Discharge Interval | 12 to 13 min | Observation Vendor trial observation | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation Centrifuge supplier trial, 22–23 October 2024 — Vendor-reported discharge interval at 40 GPM; solids packing and post-rinse needs varied with flow. |
| Automatic Recipe Flow | 50 GPM | Operating Control Configured trial recipe | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation Centrifuge supplier trial, 22–23 October 2024 — Vendor-developed automatic recipe; 10 GPM was a slow overnight option with occasional checks recommended. |
| Automatic Recipe Flow | 40 GPM | Operating Control Configured trial recipe | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation Centrifuge supplier trial, 22–23 October 2024 — Vendor-developed automatic recipe; 10 GPM was a slow overnight option with occasional checks recommended. |
| Automatic Recipe Flow | 10 GPM | Operating Control Configured trial recipe | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation Centrifuge supplier trial, 22–23 October 2024 — Vendor-developed automatic recipe; 10 GPM was a slow overnight option with occasional checks recommended. |
| Operator-Reported Flow | 40 GPM | Observation Operator trial observation | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation Centrifuge supplier operator report, 25 October 2024 — Operator report of the stated run; no reported issues during this 5,500 gallon observation. |
| Operator-Reported Outlet Turbidity | 21 NTU | Observation Operator trial observation | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation Centrifuge supplier operator report, 25 October 2024 — Operator report of the stated run; no reported issues during this 5,500 gallon observation. |
| Operator-Reported Processed Volume | 5,500 gal | Observation Operator trial observation | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation Centrifuge supplier operator report, 25 October 2024 — Operator report of the stated run; no reported issues during this 5,500 gallon observation. |
| Rental-Trial Planning Period | 1 month | Target Schedule basis | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation rental trial — Duration used for the trial installation planning. |
| Apple-Wine Inlet Turbidity | > 2,000 NTU | Observation Plant-reported operating context | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation comparison-facility apple wine from fermenters — Incoming apple wine was described as above 2000 NTU. |
| Apple-Wine Outlet Criterion | <= 60 NTU | Target Plant preference | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation comparison-facility apple wine to acetators — Desired outlet of 60 NTU or less. |
| Cider Inlet Turbidity | 750 NTU | Observation Plant-reported operating context | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation comparison-facility acetator cider to membrane-filter feed tank — Typical incoming cider reference. |
| Cider Outlet Criterion | <= 50 NTU | Target Plant preference | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation comparison-facility acetator cider to membrane-filter feed tank — Typical desired outlet at or below 50 NTU depending on speed. |
| WDV Circulation Inlet Turbidity | > 1,800 NTU | Observation Plant-reported operating context | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation comparison-facility white-distilled-vinegar membrane-filter circulation — Incoming recirculation stream was described as above 1800 NTU. |
| WDV Circulation Outlet Turbidity | 350 NTU | Observation Plant-reported operating context | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation comparison-facility white-distilled-vinegar membrane-filter circulation — Outlet reported while recirculating to remove solids. |
| WDV Circulation Flow | 25 GPM | Observation Plant-reported operating context | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation comparison-facility white-distilled-vinegar membrane-filter circulation — Flow reported for the recirculation example. |
| WDV Circulation Duration | approximately 8 h | Observation Plant-reported operating context | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation comparison-facility white-distilled-vinegar membrane-filter circulation — Approximate duration of the recirculation run. |
| Optional Trial Ethernet Run | 150 ft | Design Parameter Installation planning | Applies to: Centrifuge filtration recovery and equipment-relocation evaluation trial connectivity — Cable option conditional on IT and supplier remote-support need. |
| Bentonite-Treated Production Share | 75 % | Baseline Historical process context | Applies to: Separated filtration processing time from unattended bentonite-treatment elapsed time when evaluating post-formulation-change capacity and filter-aid demand Post-formulation-change treatment — Bentonite-treated production share — Post-formulation-change treatment |
| Untreated Production Share | 25 % | Baseline Historical process context | Applies to: Separated filtration processing time from unattended bentonite-treatment elapsed time when evaluating post-formulation-change capacity and filter-aid demand Post-formulation-change treatment — Untreated production share — Post-formulation-change treatment |
| Treatment and Processing Elapsed Time | 49 hours | Baseline Historical process context | Applies to: Separated filtration processing time from unattended bentonite-treatment elapsed time when evaluating post-formulation-change capacity and filter-aid demand Includes unattended treatment; not labor hours — Treatment and processing elapsed time — Includes unattended treatment; not labor hours |
| Post-Order Completion Window | 12 weeks | Target Schedule target | Applies to: Defined filtration quality, capacity and filter-aid cost criteria for the centrifuge option and its post-purchase-order completion plan AFE acceptance plan — Post-order completion window — AFE acceptance plan |
| Relocation Outage Allowance | 1 weeks | Estimate Schedule allowance | Applies to: Planned critical spares and supplier follow-up for an unbacked filtration system and inventory coverage during relocation of a leased unit Leased filter permanent-position relocation — Relocation outage allowance — Leased filter permanent-position relocation |