Expanded the erosion-remediation scope into a complete civil and hydraulic stormwater-control design.
Designed protection for the tank slab.
Designed measures to reduce washout risk.
Designed control of high-velocity roof runoff.
Designed drainage access and debris control to improve maintainability.
Developed a permanent drainage route for future upgrades.
Uncontrolled roof runoff created subgrade voids and slab-edge risk, so the site needed source capture, reinforced conveyance, debris screening, step-down energy dissipation, outlet protection, and phased stabilization.
Defined drainage design criteria: 545 GPM design basis, 135-ft reinforced concrete channel, 1-ft channel width, 12-in depth, 4% slope, #4 rebar, 8 in x 8 in stainless gutters with five 4 in x 5 in downspouts, 85 ft x 4 ft x 2 ft Phase 1 void, and 445 anchor. Added 4,375 cf/hr / 1.215 cfs design runoff basis at 6 in/hr; alternative 3.5 in/hr/ 2,555 cf/hr/ 318.7 GPM as design-check only; 12-18 in sidewall height; 6-in reinforced sidewalls/base; 5-7 ft/s target velocity; rectangular/U-shaped channel; flared transition to weir; expansion joints every 12-15 ft; control joints every 6 ft; 8 in crushed stone base; geotextile; 4 in perforated PVC relief lines; riprap/gabion transitions; reinforced apron; keyway/interlocking base; 12-in steel dowels every 4 ft; geo-cellular confinement / erosion-control matting; debris grates/screens.
Improved stormwater-control design and phased execution readiness.
Advanced stormwater-control design using a 545 GPM basis, a 135-ft reinforced channel, a five-step/55-ft weir, 34-degree debris-screen tilt, a 10 ft by 15 ft by 2 ft outlet basin and a Phase 1 stabilization package. The scope coordinates gutters, downspouts, channels, screens, weirs, outlet energy dissipation and slab stabilization.
Advanced tank-slab protection design.
Advanced drainage maintainability design.
Advanced phased construction readiness.
Design runoff basis: 545 GPM.
Design runoff basis: 4,375 cubic feet/hour, or approximately 1.215 cubic feet/second.
Specified channel length: 135 ft.
Specified channel slope: 4%.
Specified weir arrangement: five 5-ft drops.
Specified total weir length: 55 ft.
Specified total weir height: 25 ft.
Specified step length: 11 ft.
Specified width where used: 7 ft.
Specified outlet basin: 10 ft by 15 ft by 2 ft.
Specified debris-screen tilt: 34 degrees.